{"id":19927,"date":"2021-01-08T22:43:26","date_gmt":"2021-01-08T19:43:26","guid":{"rendered":"http:\/\/www.yomlab.com\/?p=19927"},"modified":"2021-10-09T22:25:01","modified_gmt":"2021-10-09T19:25:01","slug":"ipcomm-opc-solutions","status":"publish","type":"post","link":"https:\/\/yomscada.com\/?p=19927","title":{"rendered":"IPCOMM OPC Solutions"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;'><div class=\"fusion-builder-row fusion-row \"><div  class=\"fusion-layout-column fusion_builder_column fusion_builder_column_1_1 fusion-builder-column-1 fusion-one-full fusion-column-first fusion-column-last 1_1\"  style='margin-top:0px;margin-bottom:0px;'>\n\t\t\t\t\t<div class=\"fusion-column-wrapper\" style=\"padding: 0px 0px 0px 0px;background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"   data-bg-url=\"\">\n\t\t\t\t\t\t<div class=\"fusion-text\"><h1>IPCOMM OPC Solutions<\/h1>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" class=\"lazyload size-full wp-image-19929 alignleft\" src=\"https:\/\/i0.wp.com\/www.yomscada.com\/wp-content\/uploads\/2021\/01\/ipcomm-logo-small.gif?resize=90%2C90\" data-orig-src=\"https:\/\/i0.wp.com\/www.yomscada.com\/wp-content\/uploads\/2021\/01\/ipcomm-logo-small.gif?resize=90%2C90\" alt=\"\" width=\"90\" height=\"90\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%2790%27%20height%3D%2790%27%20viewBox%3D%270%200%2090%2090%27%3E%3Crect%20width%3D%2790%27%20height%3D%27390%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/ipcomm-logo-small.gif?resize=66%2C66&amp;ssl=1 66w, https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/ipcomm-logo-small.gif?fit=90%2C90&amp;ssl=1 90w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 90px) 100vw, 90px\" data-recalc-dims=\"1\" \/>The OPC interface is increasingly gaining in popularity in automation technology. Thanks to its <img loading=\"lazy\" class=\"lazyload size-full wp-image-19928 alignright\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27200%27%20height%3D%27101%27%20viewBox%3D%270%200%20200%20101%27%3E%3Crect%20width%3D%27200%27%20height%3D%273101%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"http:\/\/www.yomscada.com\/wp-content\/uploads\/2021\/01\/OPC-Member-200.jpg\" alt=\"\" width=\"200\" height=\"101\" \/>high degree of functionality and interoperability it is frequently used for connecting telecontrol and automation devices to SCADA and HMI systems. As a member of the\u00a0<a href=\"http:\/\/www.opcfoundation.org\/\">OPC Foundation<\/a>\u00a0we are dedicated to maintaining the compatibility of our products with the OPC standard and products of other vendors. We are able to offer these OPC family interfaces;<\/p>\n<p>The following Windows operating systems* are supported:<br \/>\nWindwos XP, Windows Server 2003, Windows Vista, Windows 7, Windows Server 2008 (R2), Windows 8, Windows 8.1, Windows Server 2012 (R2)<\/p>\n<ul>\n<li>OPC DA 3.0 Server can be used together with ipConvOPC or ipConv and Windows operating systems*..<\/li>\n<li style=\"text-align: justify;\">OPC UA 1.02 Server and OPC DAXML 1.01 Server can be used together with ipConvLite, ipConvOPC and ipConv both under Linux and Windows*.<\/li>\n<li>OPC DA 3.0 Client can be used together with ipConvOPC or ipConv and Windows operating systems*.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong>You want to connect telecontrol or automation devices using protocols such as IEC 60870-5-101, IEC 60870-5-104 etc. to a SCADA or HMI system via the OPC interface&#8230;<\/strong><\/p>\n<p style=\"text-align: justify;\">Supplied as a complete software package for the Windows NT\/2000\/2003\/XP operating systems, ipConvOPC is a cost-effective solution. The software can either be installed directly at the control station or on a separate system. Telecontrol and automation devices can be connected via selected protocols.<\/p>\n<p style=\"text-align: justify;\">Other options are OPC DA 3.0 Server or OPC DAXML 1.01 Server to enable data exchange with the OPC DA or OPC DAXML client.<\/p>\n<p style=\"text-align: justify;\">Based on the OPC standard, our ipConvOPC can be used with any control station for instance YOM SCADA and is compatible with control technology by any other vendors such as VA TECH SAT, AREVA or Emerson .<\/p>\n<p>This enables telecontrol or automation devices to be connected to almost any control station with an OPC client.<\/p>\n<p><strong>You want to connect various telecontrol or automation devices (slave) to several different control stations (master)&#8230;<\/strong><\/p>\n<p>The ipConvOPC software package may include several protocol modules (master\/slave) allowing the connection of different telecontrol or automation devices to different control stations.<br \/>\nThe ipConvOPCsoftware needs to be installed on a separate Windows node workstation to implement this application.<\/p>\n<p style=\"text-align: justify;\"><strong>You want to connect telecontrol or automation devices (slave) to the control station by integration in the (TCP\/IP) network using the OPC interface&#8230;<\/strong><\/p>\n<p style=\"text-align: justify;\">ipEther232 &#8211; The RS232\/Ethernet Converter enables the transmission of serial protocols such as IEC 60870-5-101 over the Ethernet or TCP\/IP networks.\u00a0 The ipConvOPC software package installed on the workstation of the control center effects the conversion from IEC 60870-5-101 to OPC.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div>\n\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":19931,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[68],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IPCOMM OPC Solutions - YOMLAB SCADA Technologies<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yomscada.com\/?p=19927\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IPCOMM OPC Solutions - YOMLAB SCADA Technologies\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yomscada.com\/?p=19927\" \/>\n<meta property=\"og:site_name\" content=\"YOMLAB SCADA Technologies\" \/>\n<meta property=\"article:published_time\" content=\"2021-01-08T19:43:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-10-09T19:25:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yomscada.com\/wp-content\/uploads\/2021\/01\/IPC.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"230\" \/>\n\t<meta property=\"og:image:height\" content=\"230\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"YomAdmin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"YomAdmin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/yomscada.com\/?p=19927#article\",\"isPartOf\":{\"@id\":\"https:\/\/yomscada.com\/?p=19927\"},\"author\":{\"name\":\"YomAdmin\",\"@id\":\"https:\/\/yomscada.com\/#\/schema\/person\/6d884c19da0de3178ac1feb32f9bf34b\"},\"headline\":\"IPCOMM OPC Solutions\",\"datePublished\":\"2021-01-08T19:43:26+00:00\",\"dateModified\":\"2021-10-09T19:25:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/yomscada.com\/?p=19927\"},\"wordCount\":612,\"publisher\":{\"@id\":\"https:\/\/yomscada.com\/#organization\"},\"articleSection\":[\"Urunler\"],\"inLanguage\":\"tr\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/yomscada.com\/?p=19927\",\"url\":\"https:\/\/yomscada.com\/?p=19927\",\"name\":\"IPCOMM OPC Solutions - YOMLAB SCADA Technologies\",\"isPartOf\":{\"@id\":\"https:\/\/yomscada.com\/#website\"},\"datePublished\":\"2021-01-08T19:43:26+00:00\",\"dateModified\":\"2021-10-09T19:25:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/yomscada.com\/?p=19927#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/yomscada.com\/?p=19927\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/yomscada.com\/?p=19927#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana sayfa\",\"item\":\"https:\/\/yomscada.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IPCOMM OPC Solutions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/yomscada.com\/#website\",\"url\":\"https:\/\/yomscada.com\/\",\"name\":\"YOMLAB SCADA Technologies\",\"description\":\"YOM SCADA and Report Technologies\",\"publisher\":{\"@id\":\"https:\/\/yomscada.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/yomscada.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/yomscada.com\/#organization\",\"name\":\"YOMLAB SCADA Technologies\",\"url\":\"https:\/\/yomscada.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/yomscada.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/yom_mobile_logo.png?fit=376%2C114&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/yom_mobile_logo.png?fit=376%2C114&ssl=1\",\"width\":376,\"height\":114,\"caption\":\"YOMLAB SCADA Technologies\"},\"image\":{\"@id\":\"https:\/\/yomscada.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/yomscada.com\/#\/schema\/person\/6d884c19da0de3178ac1feb32f9bf34b\",\"name\":\"YomAdmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\/\/yomscada.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d43631a82fe4282144227908747a0782?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d43631a82fe4282144227908747a0782?s=96&d=mm&r=g\",\"caption\":\"YomAdmin\"},\"sameAs\":[\"http:\/\/www.yomlab.com\"],\"url\":\"https:\/\/yomscada.com\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IPCOMM OPC Solutions - YOMLAB SCADA Technologies","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yomscada.com\/?p=19927","og_locale":"tr_TR","og_type":"article","og_title":"IPCOMM OPC Solutions - YOMLAB SCADA Technologies","og_url":"https:\/\/yomscada.com\/?p=19927","og_site_name":"YOMLAB SCADA Technologies","article_published_time":"2021-01-08T19:43:26+00:00","article_modified_time":"2021-10-09T19:25:01+00:00","og_image":[{"width":230,"height":230,"url":"https:\/\/yomscada.com\/wp-content\/uploads\/2021\/01\/IPC.jpg","type":"image\/jpeg"}],"author":"YomAdmin","twitter_card":"summary_large_image","twitter_misc":{"Yazan:":"YomAdmin","Tahmini okuma s\u00fcresi":"3 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yomscada.com\/?p=19927#article","isPartOf":{"@id":"https:\/\/yomscada.com\/?p=19927"},"author":{"name":"YomAdmin","@id":"https:\/\/yomscada.com\/#\/schema\/person\/6d884c19da0de3178ac1feb32f9bf34b"},"headline":"IPCOMM OPC Solutions","datePublished":"2021-01-08T19:43:26+00:00","dateModified":"2021-10-09T19:25:01+00:00","mainEntityOfPage":{"@id":"https:\/\/yomscada.com\/?p=19927"},"wordCount":612,"publisher":{"@id":"https:\/\/yomscada.com\/#organization"},"articleSection":["Urunler"],"inLanguage":"tr"},{"@type":"WebPage","@id":"https:\/\/yomscada.com\/?p=19927","url":"https:\/\/yomscada.com\/?p=19927","name":"IPCOMM OPC Solutions - YOMLAB SCADA Technologies","isPartOf":{"@id":"https:\/\/yomscada.com\/#website"},"datePublished":"2021-01-08T19:43:26+00:00","dateModified":"2021-10-09T19:25:01+00:00","breadcrumb":{"@id":"https:\/\/yomscada.com\/?p=19927#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yomscada.com\/?p=19927"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/yomscada.com\/?p=19927#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana sayfa","item":"https:\/\/yomscada.com\/"},{"@type":"ListItem","position":2,"name":"IPCOMM OPC Solutions"}]},{"@type":"WebSite","@id":"https:\/\/yomscada.com\/#website","url":"https:\/\/yomscada.com\/","name":"YOMLAB SCADA Technologies","description":"YOM SCADA and Report Technologies","publisher":{"@id":"https:\/\/yomscada.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yomscada.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/yomscada.com\/#organization","name":"YOMLAB SCADA Technologies","url":"https:\/\/yomscada.com\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/yomscada.com\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/yom_mobile_logo.png?fit=376%2C114&ssl=1","contentUrl":"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/yom_mobile_logo.png?fit=376%2C114&ssl=1","width":376,"height":114,"caption":"YOMLAB SCADA Technologies"},"image":{"@id":"https:\/\/yomscada.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yomscada.com\/#\/schema\/person\/6d884c19da0de3178ac1feb32f9bf34b","name":"YomAdmin","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/yomscada.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d43631a82fe4282144227908747a0782?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d43631a82fe4282144227908747a0782?s=96&d=mm&r=g","caption":"YomAdmin"},"sameAs":["http:\/\/www.yomlab.com"],"url":"https:\/\/yomscada.com\/?author=1"}]}},"jetpack_featured_media_url":"https:\/\/i0.wp.com\/yomscada.com\/wp-content\/uploads\/2021\/01\/IPC.jpg?fit=230%2C230&ssl=1","_links":{"self":[{"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/posts\/19927"}],"collection":[{"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yomscada.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=19927"}],"version-history":[{"count":4,"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/posts\/19927\/revisions"}],"predecessor-version":[{"id":20147,"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/posts\/19927\/revisions\/20147"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yomscada.com\/index.php?rest_route=\/wp\/v2\/media\/19931"}],"wp:attachment":[{"href":"https:\/\/yomscada.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=19927"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yomscada.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=19927"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yomscada.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=19927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}